MCQs>Engineering & Manufacturing>Energy Engineering MCQs>A pipe of diameter 0.2 m is to be fitted with a venturi meter, where the pressure head of the flowing liquid is 7.2 m and the maximum flow is 6 m3/min. What is the least diameter of the throat to make sure that the pressure head does not become negative? (Consider K = 0.96)
Energy Engineering MCQs
A pipe of diameter 0.2 m is to be fitted with a venturi meter, where the pressure head of the flowing liquid is 7.2 m and the maximum flow is 6 m3/min. What is the least diameter of the throat to make sure that the pressure head does not become negative? (Consider K = 0.96)
Answer
Correct Answer: 103.4 mm
Explanation:
Note: This Question is unanswered, help us to find answer for this one